Technical datasheets

Access OTP Keypad RT-ACS-OTP-KPD — Technical Datasheet

Last updated 5 August 2026 · Published 5 August 2026

Access OTP keypad unit (ACS) makes the access door in the secured room more secure with

One Time Password(OTP) from a centralized Server by the monitoring authority. The person

who tries to access the secured door gets intimated with OTP and that is entered into the

keypad, and then the user will be able to open the door.

The ACS is a secure system whose hardware unit is placed outside of the secure room. The

hardware system has a display, keypad for the user to enter the request, and 2 relays for

EMLock controls (one standby) safe relay mechanism to open the door of the room. The door

will automatically be closed within 30 seconds. To exit the Room, the user can use the EXIT

The system communicates to the OTP management system through the internet using a

wired Ethernet connection to the Router. The system has non-volatile memory to store

100OTPs, communicates with OMS using SIA protocol, and gets commands and data using our

The hardware system also has a potential free output which will give input to AlarmPanel on

entering a dedicated DURESS Code, tampering of the unit, force opening of the door without

the permission of the system, and also communicates these alerts to the OMS (OTP

Management System). An Alert will be sent to OMS, when the wrong password is entered

Features

  • 12V DC supply is given as input to the unit
  • User Key Entry interfaces- Keypad and LCD Display
  • Ethernet Communication interface with Protection for connectivity
  • SIA protocol for Communication
  • Rugged Cabinet
  • Solid state relay for access door operations- 2 output (1 standby) for Fail secure
  • lock operations
  • Non-volatile memory to store the 100 OTP’s
  • Potential free output contacts to the alarm panel on Duress Code entry.
  • Unit Tamper Detection.
  • Online and Offline modes of Access implementation.
  • Browser based application with login levels.

Ordering information

ModelConfiguration
RT-ACS-OTP-KPDEthernet Communication · 120X160X40

Applications

  • Vault Room
  • Server Room
  • Locker Room

This page covers the specification content of the datasheet. The PDF also contains product dimensions, calibration, certification, warranty and revision history — download it for those.

Related product line

E-Surveillance products →