PCMU (RT-PCMU-G1-00)

RT-PCMU-G1-00

PCMU

Power and communication management unit with 3-phase monitoring, battery backup, and Ethernet CMS integration

Datasheet (PDF)
Read the datasheet as a web page

Overview

Advanced power management device for remote electrical system monitoring. Features 4 digital inputs, 9 output controls, 5 load presence detectors (lobby/indoor/signage lights, 2 ACs), 3-phase AC voltage detection, UPS battery monitoring, and inbuilt battery backup. Communicates via 100Mbps Ethernet with SIA protocol to CMMS server. Supports schedule-based automation. Used in e-surveillance, banking, mobile towers, and commercial buildings.

Specifications

Product Specification

Wired Input4 no’s of Digital Input
Wired Output2 nos’ of 12VDC changeover contact, Rating 2A 2 no’s of 12VDC NO contact , Rating 2A
Wired Output with Load Presence Detection3no’s of Range- 0.5A to 5A 2no’s of Range - 5A to 30A
UPS Battery Voltage Monitor0 -240VDC ,± 5%
Battery Backup FunctionCharging Voltage: 13.5VDC, ± 5% Charging Current: 500 mA to 1A
Power Distribution6 no’s of 12.5VDC ,± 5%
CommunicationEthernet:100 Mbps-RJ45 Connector
RTCInbuilt Real Time clock
Power Output12.5VDC,8A
Power InputInput voltage: 230VAC,1A Operating voltage of Card – 12.5VDC , ± 10 %
Operating ConditionTemperature 10 C to 70 C Humidity : 20% to 80%
MechanicalMaterials: MS Size: W330 mm x H222 mm x D112 mm Weight: 3.5 Kg

Functional Specification

Sensor Functi Arm/Di Alert Input Zones Hooter Types SIA Ev Enables Type Selection –NC/NO /PIR on Type- Intruction- sarm time configuration duration time configuration of Action selection-CMS/Hooter ent Code configuration /Disable
Output ControlHooter/Other type selection 4 no’s of different schedule function Enable/Disable Auto/Manual SIA Event Code configuration Load Real On/Off Status Monitoring Hooter Duration Configuration
Curren displa Curren Batter Power Backup Management Batter config Batter SMPS Ft battery voltage reading y t SMPS Voltage Reading display y Presence detection y Low and Cutoff Voltage uration y Low and cutoff alerts ailure Alert
Curren displa UPS Battery Voltage Management Batter for Alt UPS Battery Voltage Reading y y Low Voltage configuration ert
CommunicationDevice IP and Port number configuration Target Server IP and Port number Configuration. SIA Standard Protocol
UPS battery voltage monitorCMMS Server Router Central Monitoring
12v Distribution4 no's digital input 4 no's output 5 no's load presence detection
1.Fire alarm panel 2.Camera power 3.Router power 4.Intrusion panel 5. Spare 6. Spare1.Y-Phase 1.Hooter 1.Lobby light circuit presence voltage 2.Router 2.Indoor room light 2.B-Phase 3.PoE switch 3.Signage light presence voltage 4.Intrusion panel 4.AC-1 5.AC-2 3.UPS presence output voltage
Wiring Diagram4.Spare

Ordering information

ModelConfiguration
RT-PCMU-G0TCP/IP, Ethernet · W330 x H222 x D112

Applications

  • e- Surveillance
  • Mobile Tower Management
  • Retail Shops
  • Banks/ATMs
  • Automation Controls
  • Commercial Buildings
  • Projects

Related products