PCMU RT-PCMU-G1-00 — Technical Datasheet
Last updated 5 August 2026 · Published 5 August 2026
The Power control Monitoring Unit is an advanced device designed to remotely
manage electrical and electronic systems. It provides real-time ON/OFF status
updates for connected loads, ensuring efficient power management. Equipped
with an inbuilt battery backup provision for the 12VDC system, this unit offers
reliable power continuity and control capabilities, making it an essential tool for
modern electrical maintenance and operations.
Product Specification
| Wired Input | 4 no’s of Digital Input |
|---|---|
| Wired Output | 2 nos’ of 12VDC changeover contact, Rating 2A 2 no’s of 12VDC NO contact , Rating 2A |
| Wired Output with Load Presence Detection | 3no’s of Range- 0.5A to 5A 2no’s of Range - 5A to 30A |
| UPS Battery Voltage Monitor | 0 -240VDC ,± 5% |
| Battery Backup Function | Charging Voltage: 13.5VDC, ± 5% Charging Current: 500 mA to 1A |
| Power Distribution | 6 no’s of 12.5VDC ,± 5% |
| Communication | Ethernet:100 Mbps-RJ45 Connector |
| RTC | Inbuilt Real Time clock |
| Power Output | 12.5VDC,8A |
| Power Input | Input voltage: 230VAC,1A Operating voltage of Card – 12.5VDC , ± 10 % |
| Operating Condition | Temperature 10 C to 70 C Humidity : 20% to 80% |
| Mechanical | Materials: MS Size: W330 mm x H222 mm x D112 mm Weight: 3.5 Kg |
Functional Specification
| Sensor Functi Arm/Di Alert Input Zones Hooter Types SIA Ev Enable | s Type Selection –NC/NO /PIR on Type- Intruction- sarm time configuration duration time configuration of Action selection-CMS/Hooter ent Code configuration /Disable |
|---|---|
| Output Control | Hooter/Other type selection 4 no’s of different schedule function Enable/Disable Auto/Manual SIA Event Code configuration Load Real On/Off Status Monitoring Hooter Duration Configuration |
| Curren displa Curren Batter Power Backup Management Batter config Batter SMPS F | t battery voltage reading y t SMPS Voltage Reading display y Presence detection y Low and Cutoff Voltage uration y Low and cutoff alerts ailure Alert |
| Curren displa UPS Battery Voltage Management Batter for Al | t UPS Battery Voltage Reading y y Low Voltage configuration ert |
| Communication | Device IP and Port number configuration Target Server IP and Port number Configuration. SIA Standard Protocol |
| UPS battery voltage monitor | CMMS Server Router Central Monitoring |
| 12v Distribution | 4 no's digital input 4 no's output 5 no's load presence detection |
| 1.Fire alarm panel 2.Camera power 3.Router power 4.Intrusion panel 5. Spare 6. Spare | 1.Y-Phase 1.Hooter 1.Lobby light circuit presence voltage 2.Router 2.Indoor room light 2.B-Phase 3.PoE switch 3.Signage light presence voltage 4.Intrusion panel 4.AC-1 5.AC-2 3.UPS presence output voltage |
| Wiring Diagram | 4.Spare |
Ordering information
| Model | Configuration |
|---|---|
| RT-PCMU-G0 | TCP/IP, Ethernet · W330 x H222 x D112 |
Applications
- e- Surveillance
- Mobile Tower Management
- Retail Shops
- Banks/ATMs
- Automation Controls
- Commercial Buildings
- Projects
This page covers the specification content of the datasheet. The PDF also contains product dimensions, rt-pcmu-g0, calibration, certification, warranty and revision history — download it for those.
Related product line
E-Surveillance products →