PCMU RT-PCMU-G1-00 — Technical Datasheet
Last updated 5 August 2026 · Published 5 August 2026
PCMU RT-PCMU-G1-00 — Technical Datasheet
The Power control Monitoring Unit is an advanced device designed to remotely manage electrical and electronic systems. It provides real-time ON/OFF status updates for connected loads, ensuring efficient power management. Equipped with an inbuilt battery backup provision for the 12VDC system, this unit offers reliable power continuity and control capabilities, making it an essential tool for modern electrical maintenance and operations.
Product Specification
Wired Input: 4 no’s of Digital Input
Wired Output: 2 nos’ of 12VDC changeover contact, Rating 2A 2 no’s of 12VDC NO contact , Rating 2A
Wired Output with Load Presence Detection: 3no’s of Range- 0.5A to 5A 2no’s of Range - 5A to 30A
UPS Battery Voltage Monitor: 0 -240VDC ,± 5%
Battery Backup Function: Charging Voltage: 13.5VDC, ± 5% Charging Current: 500 mA to 1A
Power Distribution: 6 no’s of 12.5VDC ,± 5%
Communication: Ethernet:100 Mbps-RJ45 Connector
RTC: Inbuilt Real Time clock
Power Output: 12.5VDC,8A
Power Input: Input voltage: 230VAC,1A Operating voltage of Card – 12.5VDC , ± 10 %
Operating Condition: Temperature 10 C to 70 C Humidity : 20% to 80%
Mechanical: Materials: MS Size: W330 mm x H222 mm x D112 mm Weight: 3.5 Kg
Functional Specification
Sensor Functi Arm/Di Alert Input Zones Hooter Types SIA Ev Enable: s Type Selection –NC/NO /PIR on Type- Intruction- sarm time configuration duration time configuration of Action selection-CMS/Hooter ent Code configuration /Disable
Output Control: Hooter/Other type selection 4 no’s of different schedule function Enable/Disable Auto/Manual SIA Event Code configuration Load Real On/Off Status Monitoring Hooter Duration Configuration
Curren displa Curren Batter Power Backup Management Batter config Batter SMPS F: t battery voltage reading y t SMPS Voltage Reading display y Presence detection y Low and Cutoff Voltage uration y Low and cutoff alerts ailure Alert
Curren displa UPS Battery Voltage Management Batter for Al: t UPS Battery Voltage Reading y y Low Voltage configuration ert
Communication: Device IP and Port number configuration Target Server IP and Port number Configuration. SIA Standard Protocol
UPS battery voltage monitor: CMMS Server Router Central Monitoring
12v Distribution: 4 no's digital input 4 no's output 5 no's load presence detection
1.Fire alarm panel 2.Camera power 3.Router power 4.Intrusion panel 5. Spare 6. Spare: 1.Y-Phase 1.Hooter 1.Lobby light circuit presence voltage 2.Router 2.Indoor room light 2.B-Phase 3.PoE switch 3.Signage light presence voltage 4.Intrusion panel 4.AC-1 5.AC-2 3.UPS presence output voltage
Wiring Diagram: 4.Spare
Ordering information
RT-PCMU-G0 — TCP/IP, Ethernet · W330 x H222 x D112
Applications
- e- Surveillance
- Mobile Tower Management
- Retail Shops
- Banks/ATMs
- Automation Controls
- Commercial Buildings
- Projects
Sections present in the PDF but not reproduced here: product dimensions, rt-pcmu-g0, calibration, certification, warranty, revision history.
Related product line
E-Surveillance products →